Why the study?

Does customizing ICD programming beyond default settings reduce inappropriate shocks in patients with ICDs?

Population

Patients with a broad spectrum of disorders associated with a high risk of sudden death receiving…

Comparison

Customizing and optimizing ICD programming vs Default or 'out the box' ICD programming settings

Design

Review

Authors

FMFadi MansourUniversity of OttawaPaul KhairyPaul KhairyElectrophysiology

Discussion

Loading...

Member takes

Implication

May support customizing ICD programming to reduce shocks; leaves open prospective validation in contemporary cohorts.

Structured PICO

Does customizing ICD programming beyond default settings reduce inappropriate shocks in patients with ICDs?

P
Population
Patients with a broad spectrum of disorders associated with a high risk of sudden death receiving implantable cardioverter-defibrillators (ICDs) for primary or secondary prevention
I
Intervention
Customizing and optimizing ICD programming (including high cutoff rates, longer detection times, antitachycardia pacing, and discriminators)
C
Comparator
Default or 'out the box' ICD programming settings
O
Outcome
Reduction of inappropriate shockssafety

Customizing ICD programming beyond default settings is an important strategy to reduce the incidence of inappropriate shocks and improve patient quality of life.

Cite This Study

Mansour et al. (2011) studied this question.

synapsesocial.com/papers/6a728a66febe604dd70aa881https://doi.org/10.1111/j.1540-8159.2011.03037.x

Topics

Cardiac device therapy
View Full Paper
Ask AI
Bookmark
Share

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Selecting the Transthoracic Defibrillation Shock Directional Vector Based on VF Amplitude Improves Shock Success2009 · 9 citations
  2. 2Combining Shock Reduction Strategies to Enhance ICD Therapy: A Role for Computer Modeling2010 · 45 citations
  3. 3Improving SVT Discrimination in Single‐Chamber ICDs: A New Electrogram Morphology‐Based Algorithm2006 · 90 citations
  4. 4The Proarrhythmic Potential of Implantable Cardioverter-Defibrillators1995 · 198 citations
  5. 5Safety and Efficacy of a Dual Chamber Implantable Cardioverter Defibrillator Capable of Slow Ventricular Tachycardia Discrimination:2003 · 9 citations