Why the study?
Is there a difference in efficacy and safety between danaparoid, enoxaparin, and dalteparin for thromboprophylaxis in patients undergoing hip fracture surgery?
Is there a difference in efficacy and safety between danaparoid, enoxaparin, and dalteparin for thromboprophylaxis in patients undergoing hip fracture surgery?
In a pilot study of patients undergoing hip fracture surgery, danaparoid, enoxaparin, and dalteparin showed similar efficacy and safety for thromboprophylaxis.
Answers are grounded in this paper and cite their sources.
Comparable safety/efficacy supports clinical equipoise among agents; pilot RCT leaves open larger definitive trials.
A pilot study was performed to compare the thromboprophylactic effect of danaparoid, enoxaparin and dalteparin in patients with hip fracture. The study was a prospective, randomised assessor-blind, four-centre trial. Prophylaxis was given for 9-11 days, whereafter bilateral phlebography was performed. A total of 197 patients were randomised. There were no statistically significant differences in the frequency of deep vein thrombosis, in blood loss or bleeding complications between the three prophylaxis groups. In conclusion, this moderately sized study revealed no statistically significant difference in efficacy or safety between danaparoid, enoxaparin and dalteparin in patients undergoing hip fracture surgery.
No takes yet. Share an insight, caveat, or question.
A 1999 study studied this question.