Within the concerted actions of the Commission's PV Pilot Plant R&D Programme a study was undertaken to determine and validate a cost-effective on-site calibration method for silicon solar sensors used in PV plants and to identify a reliable sensor design with a stable lifetime comparable to that of the modules This paper summarizes 1) the present state-of-the-art devices used for monitoring solar irradiance mostly by the PV community, 2) practices employed by device suppliers, and users in calibrating such devices, and 3) preliminary results of concerted action studies being carried out by several test centres in Europe regarding the use of Si-based devices and their calibration methods Our preliminary observations are that 1) the simplified calibration method is effective and suitable for system designers, installers, and operators, and 2) the Si-based devices evaluated (mainly monocrystalline) are cost-effective substitutes for the thermopile pyranometers.