Three coordinated measurements on the Scylla III theta-pinch yield: β, which is the ratio of plasma pressure to external magnetic field pressure; n, which is the plasma density as a function of radius; and Ti, which is the ion temperature. The three measurements are (1) a differential magnetic loop-probe measurement that determines total flux excluded by the plasma, (2) side-on-measurement of the profile of light intensity emitted by the plasma that yields the relative density profile, and (3) a side-on gas-laser interferometer measurement that gives the absolute density integrated through the plasma. Electron temperature is measured separately by x-ray absorption and it is assumed that electron and ion temperatures are not a function of radius. In the low-pressure regime, (P initial = 20 mTorr) without bias magnetic field, typical measured values are β = 0.70 ± 0.15 and ne = ni = 3.0 × 1016/cm3 on axis, Ti = 2.2 keV, and the plasma density decreases monotonically with increasing radius from the axis, reaching zero at r = 1.1 cm. In the high-pressure regime, (P initial = 100 mTorr) with reverse-bias magnetic field, typical values are β = 0.85 ± 0.15 and ne = ni = 3.5 × 1016/cm3 on axis, Ti = 1.5 keV, and the plasma density has a central core of radius ∼0.8 cm of nearly constant density.
No takes yet. Share an insight, caveat, or question.
Sawyer et al. (1967) studied this question.