Answers are grounded in this paper and cite their sources.
The effects of 10-keV X-rays and 400-keV endpoint-energy bremsstrahlung X-rays on MOS capacitors with SiO2or HfO2gate dielectrics and Al and TaSi gate metallization have been studied using the Monte Carlo simulator, MRED. We compare these calculations with previous results in the literature obtained with other Monte Carlo and discrete ordinates codes, and with experiments on devices with SiO2gate dielectrics, and find generally good agreement. There is a significant dose reduction in thin HfO2layers exposed to 10-keV X-rays, when the HfO2is surrounded by lower-Z materials (e.g., Si, Al). This dose reduction does not occur in a medium-energy bremsstrahlung X-ray environment; in that case, the dose in a HfO2gate dielectric can be ~10 times higher than the dose in a SiO2dielectric, for the same incident X-ray fluence. These results demonstrate the capability of MRED to assist in the evaluation of dose enhancement and reduction in regions including or nearby high-Z materials in microelectronic materials and devices.
No takes yet. Share an insight, caveat, or question.
Dasgupta et al. (2010) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: