Answers are grounded in this paper and cite their sources.
Absorption profiles of cesium resonance lines at 8521 and 8944 {} have been measured for the wavelength range from 0.5 to 30 {} from the line centers using a tungsten ribbon light source, cell lengths L from 0.31 to 6.1 cm, and Cs densities N from 2 ×{} 10¹⁴ to 2 ×{} 10¹⁶ cm^-3. The wavelength dependence of the absorption coefficients are consistent with a Lorentzian form and values of γfN=1.08×10^-7 and 0.30 ×{} 10^-7 cm³ sec^-1 are obtained for 8521 and 8944 {} lines. Here γ is the collisional (or Lorentzian) half-width and f is the oscillator strength. The values of γfN deduced from total fractional absorption data agree with those determined from the line profiles. Our results agree well (to within 15%) with those of Gregory and with theory, but disagree with more recent data. A source of error in some previous determinations of half-widths is the fact that even when the calculated absorption is very large, the measured transmission at the line center is significant; about 3.5 ×{} 10^-2 compared to {~} 10^-100,000 predicted from our measurements in the wings of the lines for N=1.14×10¹⁵ cm^-3 and $L=5.9$ cm. This effect is shown to result from transmission through the monochromator at wavelengths in the far wings of the instrument function.
No takes yet. Share an insight, caveat, or question.
Chen et al. (1968) studied this question.