Why the study?
TEER is widely adopted for mitral regurgitation, but personalized in silico models to predict procedural effects in advance for individual patients are needed.
Can a personalized in silico model accurately predict the post-procedural efficacy of transcatheter edge-to-edge repair for mitral regurgitation?
Can a personalized in silico model accurately predict the post-procedural efficacy of transcatheter edge-to-edge repair for mitral regurgitation?
A novel personalized in silico model can rapidly and accurately predict the hemodynamic effects of transcatheter edge-to-edge repair for mitral regurgitation, potentially aiding clinical decision support.
In recent years, transcatheter edge-to-edge repair (TEER) has been widely adopted as an effective treatment for mitral regurgitation (MR). The aim of this study is to develop a personalized in silico model to predict the effect of edge-to-edge repair in advance to the procedure for each individual patient. For this purpose, we propose a combination of a valve deformation model for computing the mitral valve (MV) orifice area (MVOA) and a lumped parameter model for the hemodynamics, specifically mitral regurgitation volume (RVol). Although we cannot obtain detailed information on the three-dimensional flow field near the mitral valve, we can rapidly simulate the important medical parameters for the clinical decision support. In the present method, we construct the patient-specific pre-operative models by using the parameter optimization and then simulate the postoperative state by applying the additional clipping condition. The computed preclip MVOAs show good agreement with the clinical measurements, and the correlation coefficient takes 0.998. In addition, the MR grade in terms of RVol also has good correlation with the grade by ground truth MVOA. Finally, we try to investigate the applicability for the predicting the postclip state. The simulated valve shapes clearly show the well-known double orifice and the improvement of the MVOA, compared with the preclip state. Similarly, we confirmed the improved reverse flow and MR grade in terms of RVol. A total computational time is approximately 8 h by using general-purpose PC. These results obviously indicate that the present in silico model has good capability for the assessment of edge-to-edge repair.
No takes yet. Share an insight, caveat, or question.
Ooida et al. (2023) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: