Answers are grounded in this paper and cite their sources.
Reported on is a photofragmentation two‐photon laser‐induced fluorescence (PF/TP‐LIF) sensor with a demonstrated capability for making simultaneous measurements of NO/NO x /NO 2 . This instrumental technique is based on the direct spectroscopic detection of NO via the TP‐LIF methodology. The measurement of NO x (NO+NO 2 ), and subsequently NO 2 , is accomplished by the photofragmentation of NO 2 at 353 nm via a XeF excimer laser. The resultant NO photofragment is then quantitatively detected using the TP‐LIF technique. The laser photolysis efficiency for NO 2 is typically 60% for NO 2 photolysis cell residence times of less than 0.5 s. The limit of detection ( S/N =2) for the described PF/TP‐LIF instrument is 3.5 pptv for NO (2 min integration time) and 10 pptv for NO 2 (6 min integration time). An assessment of chemical interferences in this system revealed no significant problems. The extension of the PF/TP‐LIF methodology to the simultaneous detection of multiple N x O y , species is discussed.
No takes yet. Share an insight, caveat, or question.
Sandholm et al. (1990) studied this question.