This is the authors' abstract. We don't add key points for this paper.
The first ion‐assisted OH measurement instrument was developed and field tested in 1989. Since that time both instrument and technique have evolved substantially and several potential measurement interferences have been investigated. Included among these are reactions that could compete with the H 2 O/SO 3 reaction, the effect Of H 2 O on the NO 3 − · HNO 3 /H 2 SO 4 reaction, and potential wall losses. These investigations have also provided data of relevance to atmospheric ion and neutral chemistry for the two reactions listed above, as well as for the OH measurement itself. Measurements made at Mauna Loa Observatory in Hawaii show for the first time a diurnal variation in tropospheric OH which spans more than 2 orders of magnitude. Nighttime measurements revealed hydroxyl radicals in the 10 4 molecules cm −3 concentration range well after dark.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Tanner et al. (1995) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: