Answers are grounded in this paper and cite their sources.
The capability of the Auto-Microbic system (Vitek Systems, Inc., Hazelwood, Mo.) has been expanded to identify members of the family Enterobacteriaceae with the use of a sealed, disposable accessory card (the Enterobacteriaceae Biochemical Card) containing 26 biochemical tests. To judge the accuracy of the AutoMicrobic system's identification in a hospital laboratory, 933 Enterobacteriaceae isolates were studied. The AutoMicrobic system provided the correct identification for 905 of the isolates (97%). For Enterobacteriaceae excluding Escherichia coli (533 isolates not E. coli), 506 isolates were correctly identified (94.9%). The AutoMicrobic system integrates well into the clinical microbiology laboratory, providing a simple, accurate, and efficient automated system for the rapid identification of Enterobacteriaceae.
No takes yet. Share an insight, caveat, or question.
Hasyn et al. (1981) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: