Answers are grounded in this paper and cite their sources.
In many industries, the effective monitoring and control of batch processes is crucial to the production of high-quality materials. Several techniques using multivariate statistical analysis have been developed for monitoring and fault detection of batch processes. Multiway principal component analysis (MPCA) has shown a powerful monitoring performance in many industrial batch processes. However, it has shortcomings that all batch lengths should be equalized and future values of batches should be estimated for on-line monitoring. In order to overcome these drawbacks and obtain better monitoring performance, we propose a new statistical method for on-line batch process monitoring that uses different unfolding method and independent component analysis (ICA). If the measured data set contains non-Gaussian latent variables, the ICA solution can extract the original source signal to a much greater extent than the PCA solution since ICA involves higher-order statistics and is not based on the assumption that the latent variables follow a multivariate Gaussian distribution. The proposed monitoring method was applied to fault detection and identification in the simulation benchmark of the fed-batch penicillin production, which is characterized by some fault sources with non-Gaussian characteristics. The simulation results clearly show the power and advantages of the proposed method in comparison to MPCA.
No takes yet. Share an insight, caveat, or question.
Lee et al. (2003) studied this question.