Key result
Corrected QT interval dispersion (QTcd) strongly indicated symptom severity in pediatric POTS, yielding an AUC of 0.986 (95% CI 0.976-0.997) and an optimal cut-off of 45 ms.
Why the study?
The study aimed to investigate factors associated with condition severity in pediatric cases with postural orthostatic tachycardia syndrome.
Does corrected QT interval dispersion (QTcd) correlate with symptom severity in pediatric patients with postural orthostatic tachycardia syndrome (POTS)?
Observational (n=296)
Does corrected QT interval dispersion (QTcd) correlate with symptom severity in pediatric patients with postural orthostatic tachycardia syndrome (POTS)?
Effect estimate: AUC 0.986 (95% CI 0.976-0.997)
p-value: p=<0.05
Corrected QT interval dispersion (QTcd) is a strong indicator of symptom severity in pediatric patients with POTS, with a cut-off of 45 ms providing high diagnostic accuracy.
QTcd may mark symptom severity in pediatric POTS; hypothesis-generating and requires prospective validation before clinical use.
Objectives: The current study aims to investigate the factors associated with the severity of conditions for pediatric cases with postural orthostatic tachycardia syndrome (POTS). Methods: Patients hospitalized and first diagnosed with POTS were retrospectively included and reviewed. The severity of symptoms was evaluated by symptom scores (SSs). Multiple Spearman correlation analyses and multiple linear regression analyses were used to determine factors independently associated with SS. Patients were divided into the mild (SS ≤ P25) and severe (SS ≥ P75) groups to test the distinguishing efficiency of the candidate factors. The efficiency of each independently correlated factor in indicating the condition of children with POTS was assessed by the receiver operating characteristic (ROC) curve. Results: A series of 296 pediatric patients aged 5–17 years suffering from POTS were included. Multiple Spearman correlation analyses and multiple linear regression analyses showed that corrected QT interval dispersion (QTcd) was independently correlated with SS (p < 0.05). QTcd can be used to suggest the severity of POTS symptoms, and the area under the curve (AUC) was 0.986 (95% CI 0.976–0.997). At a threshold of QTcd = 45 ms, the sensitivity and specificity were, respectively, 94.0% and 91.8% for symptom severity indication. Conclusions: In pediatric cases with POTS, QTcd was positively correlated with their symptom severity and exhibited a strong indicative value. A QTcd of 45 ms was a valid cut-off value for indicating symptom severity.
No takes yet. Share an insight, caveat, or question.
Cao et al. (2025) conducted an observational in Postural orthostatic tachycardia syndrome (POTS) (n=296). Corrected QT interval dispersion (QTcd) was evaluated on Symptom severity indication (severe vs mild POTS) (AUC 0.986, 95% CI 0.976-0.997, p=<0.05). Corrected QT interval dispersion (QTcd) strongly indicated symptom severity in pediatric POTS, yielding an AUC of 0.986 (95% CI 0.976-0.997) and an optimal cut-off of 45 ms.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: