Key result
Simultaneous arterial and venous imaging using 3D quantitative parameter mapping discriminated blood vessels from background with an AUC of 0.905 for arterial and 0.920 for venous images.
Why the study?
To increase the number of images that can be acquired in MR examinations using quantitative parameters, a method was developed to obtain simultaneous arterial and venous images with multi-parameter mapping at the same spatial resolution.
A novel 3D quantitative parameter mapping method can simultaneously acquire arterial and venous images with high signal intensity comparable to reference TOF and QSM methods.
PURPOSE: To increase the number of images that can be acquired in MR examinations using quantitative parameters, we developed a method for obtaining arterial and venous images with mapping of proton density (PD), RF inhomogeneity (B1), longitudinal relaxation time (T1), apparent transverse relaxation time (T2*), and magnetic susceptibility through calculation, all with the same spatial resolution. METHODS: The proposed method uses partially RF-spoiled gradient echo sequences to obtain 3D images of a subject with multiple scan parameters. The PD, B1, T1, T2*, and magnetic susceptibility maps are estimated using the quantification method we previously developed. Arterial images are obtained by adding images using optimized weights to emphasize the arteries. A morphology filter is used to obtain venous images from the magnetic susceptibility maps. For evaluation, images obtained from four out of five healthy volunteers were used to optimize the weights used in the arterial-image calculation, and the optimized weights were applied to the images from the fifth volunteer to obtain an arterial image. Arterial images of the five volunteers were calculated using the leave-one-out method, and the contrast between the arterial and background regions defined using the reference time-of-flight (TOF) method was evaluated using the area under the receiver operation characteristic curve (AUC). The contrast between venous and background regions defined by a reference quantitative susceptibility mapping (QSM) method was also evaluated for the venous image. RESULTS: The AUC to discriminate blood vessels and background using the proposed method was 0.905 for the arterial image and 0.920 for the venous image. CONCLUSION: The results indicate that the arterial images and venous images have high signal intensity at the same region as determined from the reference TOF and QSM methods, demonstrating the possibility of acquiring vasculature images with quantitative parameter mapping through calculation in an integrated manner.
No takes yet. Share an insight, caveat, or question.
Amemiya et al. (2022) studied Healthy volunteers (n=5). Simultaneous arterial and venous imaging using 3D quantitative parameter mapping vs. Reference time-of-flight (TOF) and quantitative susceptibility mapping (QSM) was evaluated on Contrast between blood vessels and background (AUC). Simultaneous arterial and venous imaging using 3D quantitative parameter mapping discriminated blood vessels from background with an AUC of 0.905 for arterial and 0.920 for venous images.