Answers are grounded in this paper and cite their sources.
The pharmacokinetics of oxycodone have been determined after single-dose administration by the intravenous (4.6-7.3 mg), oral (tablets, 9.1 mg and syrup, 9.1 mg), and rectal (30 mg) routes, in 48 patients undergoing minor surgery. There were no significant differences in the mean elimination half-lives between the intravenous (5.45 +/- 1.43 h), oral tablets (5.65 +/- 1.13 h), oral syrup (4.80 +/- 1.13 h), and rectal suppository (5.40 +/- 1.19 h) formulations of oxycodone. After intravenous administration, the mean plasma clearance of oxycodone was 25.5 +/- 10.1 L/h and the mean volume of distribution at steady state was 2.5 +/- 0.8 L/kg. The mean normalized area under the curve (AUC/D) obtained after intravenous dosing (48.2 +/- 30.2 micrograms.h/L/mg) was more than twice the AUC/D values obtained after the administration of oxycodone tablets (19.8 +/- 3.5 micrograms.h/L/mg), oxycodone syrup (17.5 +/- 5.3 micrograms.h/L/mg), and rectal suppository (20.3 +/- 5.1 micrograms.h/L/mg), indicating that the amount of oxycodone reaching the systemic circulation after the extravascular routes of administration was < 50% of that obtained after intravenous dosing. The mean absorption lag times after oxycodone tablets (0.52 +/- 0.33 h), oxycodone syrup (0.48 +/- 0.40 h), and rectal suppository (0.76 +/- 0.47 h) were consistent with the onset of pharmacological effects reported by the patients.
No takes yet. Share an insight, caveat, or question.
Leow et al. (1992) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: