Bridge scour is a major concern where water flow erodes the sediment around bridge foundations which potentially leads to bridge failure. In this experimental study, vertical wall, wing wall, oblong, and semicircular-ended vertical wall abutment were tested over duration of 24 h. The semicircular-ended vertical wall abutment was found most effective in reducing scour depth. It was protected with single vertical plate of varying heights from 0.2 times of flow depth to 0.5 times of flow depth above the bed level, placed at upstream locations from one time to six times the length of the abutment (La). The vertical plate enhances the performance potential as the height of the vertical plate increases. A single vertical plate of height 0.5 times length of abutment achieved a performance potential of 59.30% at location 5 La from the abutment. The performance of two vertical plates of height 0.5y, when placed at location 4 La and 5 La was improved by 65.71%. The optimal performance potential of 73.95% was achieved with three vertical plates positioned at locations 4 La, 5 La, and 6 La on the upstream side of the abutment. These vertical plates impart additional safety to bridge abutment against scour-related risks.
No takes yet. Share an insight, caveat, or question.
Meena et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: