Key result
The novel Vessel Network Extraction algorithm successfully removed spurious branches from skeletonized 3D images, reducing the average variance of vessel diameter from 0.11 mm to 0.04 mm.
The developed Vessel Network Extraction algorithm significantly improves the characterization of 3D pulmonary vasculature imaging by effectively removing spurious branches while preserving anatomical connectivity.
Answers are grounded in this paper and cite their sources.
May refine vessel diameter quantification in 3D vascular imaging; leaves open prospective clinical validation.
In this work, non-invasive high-spatial resolution three-dimensional (3D) X-ray micro-computed tomography (μCT) of healthy mouse lung vasculature is performed. Methodologies are presented for filtering, segmenting, and skeletonizing the collected 3D images. Novel methods for the removal of spurious branch artefacts from the skeletonized 3D image are introduced, and these novel methods involve a combination of distance transform gradients, diameter-length ratios, and the fast marching method (FMM). These new techniques of spurious branch removal result in the consistent removal of spurious branches without compromising the connectivity of the pulmonary circuit. Analysis of the filtered, skeletonized, and segmented 3D images is performed using a newly developed Vessel Network Extraction algorithm to fully characterize the morphology of the mouse pulmonary circuit. The removal of spurious branches from the skeletonized image results in an accurate representation of the pulmonary circuit with significantly less variability in vessel diameter and vessel length in each generation. The branching morphology of a full pulmonary circuit is characterized by the mean diameter per generation and number of vessels per generation. The methods presented in this paper lead to a significant improvement in the characterization of 3D vasculature imaging, allow for automatic separation of arteries and veins, and for the characterization of generations containing capillaries and intrapulmonary arteriovenous anastomoses (IPAVA).
No takes yet. Share an insight, caveat, or question.
Chadwick et al. (2021) studied Healthy mouse lung vasculature. Vessel Network Extraction algorithm vs. Unfiltered skeletonized images was evaluated on Average variance of vessel diameter. The novel Vessel Network Extraction algorithm successfully removed spurious branches from skeletonized 3D images, reducing the average variance of vessel diameter from 0.11 mm to 0.04 mm.
Synapse has enriched 10 related papers. Consider them for comparative context: