Magnesium-yttrium (Mg-Y) alloys containing 7 at% to 26 at% solute were fabricated using magnetron cosputter deposition. X-ray diffraction (XRD) revealed that no second phases were present in any of the alloys and that all but two of the alloys (Mg-7% Y and Mg-14% Y) were nanocrystalline and/or amorphous. Anodic potentiodynamic polarization performed in 0.1 M sodium chloride (NaCl) at both near-neutral and high pH values showed improved anodic polarization behavior for most of the alloys when compared to either pure Mg or one of the most corrosion-resistant commercial Mg alloys (alloy WE43 [UNS M18430]). In the high-pH solution, it was not uncommon for breakdown potentials (Eb) of the Mg-Y alloys to be 2,000 mV higher than values for alloy WE43. Long-term galvanic and potentiostatic testing was performed on selected alloys to verify anodic polarization behavior. Potentiostatic testing also was performed in a pH 12 buffer solution. When defects did not affect corrosion behavior, low current density values were obtained, with one specimen exhibiting a current density of 0.9 μA/cm2 (5.8 μA/in.2) at a potential > 300 mVSCE. X-ray photoelectron spectroscopy (XPS) conducted on Mg-22% Y revealed Y was enriched significantly in the passive film once the alloy was immersed in solution. This presence of oxidized Y in the passive film was believed to be responsible for the exceptional corrosion resistance of these alloys.
No takes yet. Share an insight, caveat, or question.
Miller et al. (1995) studied this question.
Synapse has enriched 3 closely related papers on similar clinical questions. Consider them for comparative context: