Key result
Implantation of a closed-loop spinal cord stimulation system in a patient with an implantable cardioverter defibrillator provided 80% pain relief at 3 months without any device interference.
Why the study?
Because spinal cord stimulation devices and implantable cardioverter defibrillators both rely on electrical current, concerns exist regarding potential interference between them that could lead to severe consequences.
Can a closed-loop spinal cord stimulation system be safely used for pain management without interference in a patient with an implantable cardioverter defibrillator?
Case Report (n=1)
No
Can a closed-loop spinal cord stimulation system be safely used for pain management without interference in a patient with an implantable cardioverter defibrillator?
Answers are grounded in this paper and cite their sources.
A closed-loop spinal cord stimulation system can be safely implanted and operated in a patient with an ICD without causing device interference, providing effective pain relief.
Introduction: Spinal cord stimulation (SCS) devices and implantable cardioverter defibrillators (ICDs) are well-established therapies for chronic pain management and mortality prevention in cardiovascular pathologies, respectively. As both devices rely on electrical current, there are concerns regarding potential interference between them that could lead to severe consequences. Methods: In this case report, we describe the case of a 50-year-old woman who had been implanted with an ICD for 5 years due to ischemic cardiopathy and class III heart failure symptoms, and who was referred to the Pain Unit after 4 years of persistent pain on the soles of her feet, which had not responded to opioids nor to percutaneous procedures. Thus, after being deemed suitable by anesthesiologists and obtaining psychological approval, she underwent implantation of an SCS closed-loop system. Results: Three months after the procedure, she reported an 80% relief of her pain. Both devices effectively functioned at all times, and no interference was observed. Conclusion: Pain management using a closed-loop SCS in a patient with an ICD can be safely performed without interference between the devices.
No takes yet. Share an insight, caveat, or question.
Romero-Serrano et al. (2025) conducted a case report in Neuropathic pain in a patient with an implantable cardioverter defibrillator (n=1). Closed-loop spinal cord stimulation (SCS) system was evaluated on Pain relief and device interference. Implantation of a closed-loop spinal cord stimulation system in a patient with an implantable cardioverter defibrillator provided 80% pain relief at 3 months without any device interference.