We developed a highly sensitive magnetometer with continuous excitation (CE) Ramsey protocol for (111) diamonds. The distinctive feature of the magnetometer is the magnet array and antenna design to realize a uniform bias field and efficient application of quantum manipulation techniques of spin bath driving and double quantum Ramsey in millimeter‐scale spin ensembles directed to the surface normal. CE‐ and pulsed‐Ramsey show dephasing times of and , respectively, with an excitation power of 160 mW. Analysis of the compositions of dephasing factors unveils the dephasing channels limiting the dephasing time. Thanks to the long dephasing time, a sensitivity of is achieved in CE‐Ramsey. Furthermore, the comparison of sensitivity between CE‐ and pulsed‐Ramsey indicated that the noise induced by laser pulsing exists. This work paves the way for realizing ultra‐high sensitivity magnetometers with simple implementation.