A multiple‐point sheet sensor was used to measure the bite force applied to raw and cooked apple specimens during the first bite with incisors. Wedge penetration tests were compared with human bite measurements on the same samples. The shape of the force‐time curves during biting of cooked apples clearly differed from that for raw apples. The first curve of cooked apple biting became jagged, and the maximum force was reduced. The second curve emerged following the first curve in most subjects as a characteristic feature of cooked apple biting, whereas it was not seen in the bite curve of a raw specimen or the wedge penetration curve of a cooked specimen. The maximum force for tissue fracture decreased for cooked apples, but the duration of biting increased. No adequate counterparts for the impulse of biting could be obtained from the load‐displacement curves of the wedge penetration tests. The existence of parameters only measurable by bite tests and not by mechanical tests suggests the necessity of directly measuring the human bite.