Key result
Dialysis unit blood pressure showed poor agreement with interdialytic ambulatory blood pressure (Lin's concordance correlation coefficients 0.64 to 0.81), with greater bias at higher BP levels.
Why the study?
Does dialysis unit blood pressure measurement agree with interdialytic ambulatory blood pressure in Chinese dialysis patients?
Cohort (n=90)
Does dialysis unit blood pressure measurement agree with interdialytic ambulatory blood pressure in Chinese dialysis patients?
Dialysis unit blood pressure measurements show poor agreement with interdialytic ambulatory blood pressure, particularly in patients with more severe hypertension.
Dialysis unit BP warrants caution for hypertension assessment in hemodialysis; leaves open whether ambulatory monitoring improves risk stratification in this population.
Although ambulatory blood pressure (ABP) monitoring (ABPM) is often considered to have an advantage over dialysis unit blood pressure (BP) in dialysis patients, the exact relationship between these two measurements of BP has not been well determined. In a cohort of 90 Chinese dialysis patients, agreement between dialysis unit BP (predialysis and postdialysis BP) and interdialytic ABP was evaluated using Bland-Altman plots and Lin's concordance correlation coefficient for quantitative analysis, and inter-rater agreement (κ) for qualitative analysis. Limits of agreement between dialysis unit BP and ABP were wide (predialysis systolic BP: -33.5 to 20.9 mm Hg; predialysis diastolic BP: -22.2 to 11.9 mm Hg; postdialysis systolic BP: -25.4 to 26.5 mm Hg; postdialysis diastolic BP: -18.4 to 12.3 mm Hg). Lin's concordance correlation coefficient exhibited a poor agreement with concordance correlation coefficients of 0.75, 0.81, 0.64, and 0.75 for predialysis systolic BP, postdialysis systolic BP, predialysis diastolic BP, and postdialysis diastolic BP, respectively. When BP level was classified into quartiles, an increasing trend for incorrect classification rate was observed with deleterious hypertension, with the highest value in grade 3 hypertension (100% and 75.0% for predialysis and postdialysis BP, respectively). Therefore, these data suggest that agreement between dialysis unit BP and interdialytic ABP is poor in Chinese dialysis patients, and the bias for patients with higher degree of hypertension is more prominent.
No takes yet. Share an insight, caveat, or question.
Liu et al. (2014) conducted a cohort in Dialysis (n=90). Dialysis unit blood pressure measurement vs. Interdialytic ambulatory blood pressure monitoring was evaluated on Agreement between dialysis unit BP and interdialytic ABP. Dialysis unit blood pressure showed poor agreement with interdialytic ambulatory blood pressure (Lin's concordance correlation coefficients 0.64 to 0.81), with greater bias at higher BP levels.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: