Perforation of the femoral shaft by the prosthetic stem as a complication of total hip replacement is not well described in the literature. We studied twelve patients with this complication in order to define the predisposing factors, optimum management, and long-term outcome. Each patient was found to have one or more of the following factors: female sex, osteoporosis, previous fracture, or previous surgery. Once the complication was recognized, management consisted of protected weight-bearing for six weeks. All but two of the patients were asymptomatic after an average follow-up of five years. Judging from the long-term roetgenographic follow-up, penetration of the femoral shaft does not appear to seriously compromise the fixation of the femoral component.
No takes yet. Share an insight, caveat, or question.
Pellicci et al. (1980) studied this question.