Key result
The nano-copper enhanced flexible device improved the signal-to-noise ratio for ECG measurement at rest compared to a bare microelectrode.
Why the study?
A device that simultaneously measures electro-cardiac signals and respiratory pressure could provide vital signs for early warning of cardiopulmonary-related chronic diseases.
Does a nano-copper enhanced flexible device improve the measurement sensitivity and signal-to-noise ratio of human cardiopulmonary activities compared to a non-modified device?
Does a nano-copper enhanced flexible device improve the measurement sensitivity and signal-to-noise ratio of human cardiopulmonary activities compared to a non-modified device?
A novel nano-copper enhanced flexible device demonstrates high sensitivity and signal-to-noise ratio for simultaneous, non-invasive monitoring of respiratory and electro-cardiac signals.
Answers are grounded in this paper and cite their sources.
Device integration shows feasibility for simultaneous cardiopulmonary sensing; leaves open clinical validation for early disease prediction.
Background: Cardiopulmonary activities reflect the ability of the human heart to pump blood and the lungs to inhale oxygen. Thus, a device could simultaneously measure electro-cardiac signal and respiratory pressure could provide vital signs for predicting early warning of cardio-pulmonary function-related chronic diseases such as cardiovascular disease, and respiratory system disease. Results: In this study, a flexible device integrated with piezo-resistive sensing element and voltage-sensing element was developed to simultaneously measure human respiration and electro-cardiac signal (including respiratory pressure, respiration frequency, and respiration rhythm; electro-cardio frequency, electro-cardio amplitude, and electro-cardio rhythm). When applied to the measurement of respiratory pressure, the piezo-resistive performance of the device was enhanced by nano-copper modification, which detection limitation of pressure can reduce to 100 Pa and the sensitivity of pressure can achieve to 0.053 ± 0.00079 kPa -1 . In addition, the signal-to-noise ratio during bio-electrical measurement was increased to 10.7 ± 1.4, five times better than that of the non-modified device. Conclusion: This paper presents a flexible device for the simultaneous detection of human respiration and cardiac electrical activity. To avoid interference between the two signals, the layout of the electrode and the strain sensor was optimized by FEA simulation analysis. To improve the piezo-resistive sensitivity and bio-electric capturing capability of the device, a feather-shaped nano-copper was modified onto the surface of carbon fiber. The operation simplicity, compact size, and portability of the device open up new possibilities for multi-parameter monitoring.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2020) studied Healthy volunteers (n=17). Nano-copper enhanced flexible device vs. Bare carbon fiber device (without nano-copper) was evaluated on Signal-to-noise ratio (S/N) for ECG at resting state (p=0.007). The nano-copper enhanced flexible device improved the signal-to-noise ratio for ECG measurement at rest compared to a bare microelectrode.