This paper introduces a new single-phase high power factor rectifier, which features regulation by conventional PWM, soft commutation and instantaneous average line current control. Furthermore, thanks to the use of a single converter, instead of the conventional configuration composed of a four-diode front-end rectifier followed by a boost converter, a significant reduction in the conduction losses is achieved. A prototype rated at 1.6 kW, operating at 70 kHz, with an input AC voltage of 220 Vrms and an output voltage of 400 V/sub DC/ has been implemented in the laboratory. An efficiency of 97.8 % at 1.6 kW has been measured. Analysis, design, and the control circuitry are also presented in the paper.>
No takes yet. Share an insight, caveat, or question.
Souza et al. (1995) studied this question.
Synapse has enriched 3 closely related papers on similar clinical questions. Consider them for comparative context: