Why the study?
Ankle brachial index screening is time-consuming and technically difficult in diabetic patients, and hemodynamic techniques such as systolic rise time require validation.
Does systolic rise time measured by photoplethysmography correlate with ultrasound Doppler measurements in patients with peripheral arterial disease?
Does systolic rise time measured by photoplethysmography correlate with ultrasound Doppler measurements in patients with peripheral arterial disease?
Photoplethysmography is a reliable, easy-to-use alternative to ultrasound Doppler for measuring systolic rise time in PAD screening, particularly in non-diabetic patients.
SRT by PPG correlates with Doppler in this pilot; hypothesis-generating for simpler PAD screening, prospective validation required before adoption.
Aims Peripheral arterial disease (PAD) is a major public health burden requiring more intensive population screening. Ankle brachial index (ABI) using arm and ankle cuffs is considered as the reference method for the detection of PAD. Although it requires a rigorous methodology by trained operators, it remains time-consuming and more technically difficult in patients with diabetes due to mediacalcosis. Techniques based on the study of hemodynamic, such as the systolic rise time (SRT), appear promising but need to be validated. We retrospectively compared the reliability and accuracy of SRT using a photoplethysmography (PPG) technique to the SRT measured by ultrasound doppler (UD) in PAD patients diagnosed with the ABI (137 patients, 200 lower limbs). Methods and results There was a significant correlation between SRT measured with UD (SRTud) compared with that with PPG (SRTppg, r = 0.25; P = 0.001). Best correlation was found in patients without diabetes (r = 0.40; P = 0.001). Bland and Altman analysis showed a good agreement between the SRTud and SRTppg. In contrast, there was no significant correlation between UD and PPG in diabetes patients. Furthermore, patients with diabetes exhibited a significant increase of SRTppg (P = 0.02) compared with patients without diabates but not with the SRTud (P = 0.18). The SRTppg was significantly linked to the arterial velocity waveforms, the type of arterial lesion but not vascular surgery revascularization technique. Conclusion This monocentric pilot study shows that SRT measured with the PPG signal reliably correlates with SRT recorded with UD. The PPG is an easy to use technique in the hand of non-expert with a potential interest for general screening of PAD, especially in diabetes patients, due to its ease to use.
No takes yet. Share an insight, caveat, or question.
Amrani et al. (2022) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: