Why the study?
Does ablation with contact force-sensing catheters reduce arrhythmia recurrences in patients with persistent atrial fibrillation?
Does ablation with contact force-sensing catheters reduce arrhythmia recurrences in patients with persistent atrial fibrillation?
The use of contact force-sensing catheters during persistent AF ablation is associated with shorter procedure times and a significantly lower risk of arrhythmia recurrence compared to non-CF catheters.
Answers are grounded in this paper and cite their sources.
CF-sensing use in PersAF ablation shortens procedures and fluoroscopy; leaves open whether it improves arrhythmia-free survival in routine care.
INTRODUCTION: Arrhythmia recurrences remain common after ablation of persistent atrial fibrillation (PersAF). Contact force (CF)-sensing catheters have been introduced for objective assessment of contact during radiofrequency application and have been suggested to improve outcomes in ablation of paroxysmal AF, but little is known about their role in PersAF ablation. We aimed to compare the procedural profiles and outcomes of (PersAF) ablation with or without using CF-sensing catheters. METHODS: All consecutive patients undergoing first time ablation for PersAF between April 2014 and January 2015 at the Cleveland Clinic were included. Substrate modification was performed in addition to isolation of the pulmonary veins. Success rates were determined off antiarrhythmics over 1 year of follow-up. RESULTS: The study included 174 patients (77 CF and 97 non-CF). Ablation with CF-sensing catheters resulted in shorter procedures (median 204 vs. 216 minutes, P = 0.04) and shorter fluoroscopy time (36 vs. 48 minutes, P = 0.0005), without statistical difference in radiation dose (225 vs. 270 milligrays, P = 0.1). Arrhythmia recurrences were less likely to be observed in the CF-sensing group (27.6% vs. 46.4%, P = 0.01, log-rank P = 0.004). In multivariable Cox analyses, the use of CF-sensing catheters was associated with a lower risk of arrhythmia recurrence (hazard ratio 0.49, 95% confidence interval 0.27-0.85, P = 0.01). CONCLUSIONS: Compared to non-CF sensing, the use of CF-sensing catheters for PersAF ablation is associated with shorter procedures, shorter fluoroscopy time, and reduction in arrhythmia recurrences.
No takes yet. Share an insight, caveat, or question.
Hussein et al. (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: