Cloud-chamber tracks of mesotrons having momenta between 1.25×{}10⁸ ev/c and 2.5×{}10⁸ ev/c were photographed at an altitude of 3.5 km. Mesotrons in this momentum range were selected by a specially designed anticoincidence circuit. The tracks were curved by a magnetic field of 1670 gausses. A 1.25-cm lead plate above the chamber and two 1-cm lead plates within the chamber enabled one to distinguish electrons from mesotrons by multiplication phenomena. Mesotrons of these momenta easily penetrate several centimeters of lead, while protons of equal momenta have a range in lead of less than 0.2 mm. Thus, confusion of protons with mesotrons was very unlikely. Examination of 320 mesotron tracks which traversed both lead plates in the chamber and had momenta in the selected range showed that 47.2 percent of the mesotrons carried positive charges while the remaining 52.8 percent were negative. Hence, within the ±{}5.6 percent precision of this experiment, positive and negative mesotrons having energies between 0.6×{}10⁸ ev and 1.7×{}10⁸ ev occur in equal numbers at an elevation of 3.5 km.
No takes yet. Share an insight, caveat, or question.
Malcolm Correll (1947) studied this question.