Answers are grounded in this paper and cite their sources.
Feasibility study demonstrates accurate vectorcardiographic triggering for seven-tesla cardiovascular MRI in healthy volunteers, overcoming magnetohydrodynamic signal distortion.
Objective Ultra-high-field (B 0 ≥ 7 Tesla) cardiovascular magnetic resonance (CMR) offers increased resolution. However, ECG gating is impacted by the magneto-hydrodynamic (MHD) effect distorting the ECG trace. We explored the technical feasibility of a 7T MR scanner using ECG trigger learning algorithm to quantitatively assess cardiac volumes and vascular flow. Methods 7T scans performed on 10 healthy volunteers on a whole-body research MRI (Siemens Healthcare, Erlangen, Germany) with 8 channel Tx/32 channel Rx cardiac coil (MRI Tools GmbH, Berlin, Germany). Vectorcardiogram ECG was performed using a learning phase outside of the magnetic field, with a trigger algorithm overcoming severe ECG signal distortions. Vectorcardiograms were quantitatively analyzed for false negative and false positive events. Cine CMR was performed after 3 rd -order B 0 shimming using a high-resolution breath-held ECG-retro-gated segmented spoiled gradient echo, and 2D phase contrast flow imaging. Artefacts were assessed using a semi-quantitative scale. Results 7T CMR scans were acquired in all patients (100%) using the VCG learning method. 3,142 R-waves were quantitatively analyzed, yielding sensitivity 97.6%, specificity 98.7%. Mean image quality score was 0.9, sufficient to quantitate both cardiac volumes, ejection fraction (EF), aortic and pulmonary blood flow. Mean LVEF was 56.4%, RVEF 51.4%. Conclusion Reliable cardiac ECG triggering is feasible in healthy volunteers at 7T utilizing a state-of-the-art 3-lead trigger device despite signal distortion from the MHD effect. This provides sufficient image quality for quantitative analysis. Other ultra-high-field imaging applications such as human brain functional MRI with physiologic noise correction may benefit from this method of ECG triggering. Key points Ultra-high field 7 Tesla cardiac MRI is challenging due to the impact of the magneto-hydrodynamic (MHD) effect causing severe distortions in the ECG trace. Using VCG with a learning phase outside the ultra-high field magnet, the R waves can be adequately detected to perform high quality Cardiac MRI scans, overcoming signal distortion from the MHD effect.
No takes yet. Share an insight, caveat, or question.
Hamilton‐Craig et al. (2021) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: