Why the study?
Chicken-wing LAA morphology poses procedural challenges often requiring strategies like the sandwich technique, but procedural and follow-up data on this approach are scarce.
Is the 'sandwich' technique for left atrial appendage occlusion safe and feasible in patients with chicken-wing LAA anatomies?
Is the 'sandwich' technique for left atrial appendage occlusion safe and feasible in patients with chicken-wing LAA anatomies?
The 'sandwich' technique for LAA occlusion using Amplatzer devices is highly successful and safe in patients with challenging chicken-wing LAA anatomies.
Sandwich technique appears feasible for chicken wing LAAO; leaves open long-term safety and efficacy in larger cohorts.
OBJECTIVES: To describe imaging assessment, procedural and follow-up outcome of patients undergoing left atrial appendage (LAA) occlusion (LAAO) using a "sandwich" technique. BACKGROUND: The presence of a LAA with chicken wing morphology constitutes a challenge that sometimes requires specific occlusion strategies like the "sandwich" technique. However, procedural and follow-up data focusing on this implanting strategy is scarce. METHODS: This multicenter study collected individual data from eight centers between 2012 and 2019. Consecutive patients with chicken-wing LAAs defined as an early (<20 mm from the ostium) and severe bend (>90°) who underwent LAAO with Amplatzer devices and using the "sandwich" technique were included in the analysis. RESULTS: Overall, 190 subjects were enrolled in the study. Procedures were done with the Amulet device (85%) and the Amplatzer Cardiac Plug (15%). Successful implantation was achieved in 99.5% with ≤1 partial recapture in 80% of cases. Single (46.2%) and dual antiplatelet therapy (39.4%) were the most used antithrombotic therapies after LAAO. In-hospital major adverse events rate was 1.5% with no deaths. One patient (0.5%) had cardiac tamponade requiring percutaneous drainage. With a mean follow-up of 19.6 ± 14.8 months, the mortality and stroke rates were 7.7%/year and 2.5%/year, respectively. Follow-up transesophageal echocardiography (TEE) at 2-3 months showed device-related thrombosis in 2.8% and peri-device leak ≥3 mm in 1.2% of patients. CONCLUSIONS: In a large series of patients with chicken wing LAA anatomies undergoing LAAO, the use of the "sandwich" technique was feasible and safe. Preprocedural imaging was a key-factor to determine specific measurements.
No takes yet. Share an insight, caveat, or question.
Freixa et al. (2021) studied this question.