Highlights a fatal complication of pericardial tamponade resulting from central venous catheterization and hyperalimentation in a very low birthweight infant.
Answers are grounded in this paper and cite their sources.
May warrant vigilance for tamponade with malpositioned neonatal central catheters; extends sparse literature on hyperalimentation complications in very low birthweight infants.
A very low birthweight infant developed pericardial tamponade secondary to leakage of fat emulsion through a catheter lodged in the right atrial appendage. At autopsy examination a thrombus was lodged in the appendage, which presumably resulted in immobilization of the catheter and leakage of the fluid through an attenuated and necrotic myocardial wall.
No takes yet. Share an insight, caveat, or question.
Rogers et al. (1990) studied this question.