The study aimed to evaluate the diagnostic yield of an EEG seizure-detector algorithm using a wearable device and assess user experience in patients with focal refractory epilepsy.
Does a wearable EEG device accurately detect seizures and provide a good user experience in patients with focal refractory epilepsy?
Does a wearable EEG device accurately detect seizures and provide a good user experience in patients with focal refractory epilepsy?
A wearable behind-the-ear EEG device for focal seizure detection showed low sensitivity and high false alarm rates, limiting its current clinical implementation despite being generally well received.
Answers are grounded in this paper and cite their sources.
Supports feasibility of wearable EEG for focal epilepsy monitoring; leaves open need for algorithm refinement before routine outpatient use.
OBJECTIVE: The aim is to report the performance of an electroencephalogram (EEG) seizure-detector algorithm on data obtained with a wearable device (WD) in patients with focal refractory epilepsy and their experience. METHODS: Patients used a WD, the Sensor Dot (SD), to measure two channels of EEG using dry electrode patches during presurgical evaluation and at home for up to 8 months. An automated seizure detection algorithm flagged EEG regions with possible seizures, which we reviewed to evaluate the algorithm's diagnostic yield. In addition, we collected data on usability, side effects, and patient satisfaction with an electronic seizure diary application (Helpilepsy). RESULTS: Sixteen inpatients used the SD for up to 5 days and had 21 seizures. Sixteen outpatients used the device for up to 8 months and reported 101 focal impaired awareness seizures during the periods selected for analysis. Focal seizure detection sensitivity based on behind-the-ear EEG was 52% in inpatients and 23% in outpatients. False detections/h, positive predictive value (PPV), and F1 scores were 7.13%, .11%, and .002% for inpatients and 7.77%, .04%, and .001% for outpatients. Artifacts and low signal quality contributed to poor performance metrics. The seizure detector identified 19 nonreported seizures during sleep, when the signal quality was better. Regarding patients' experience, the likelihood of using the device at 6 months was 62%, and side effects were the main reason for dropping out. Finally, daily and monthly questionnaire completion rates were 33% and 65%, respectively. SIGNIFICANCE: Focal seizure detection sensitivity based on behind-the-ear EEG was 52% in inpatients and 23% in outpatients, with high false alarm rates and low PPV and F1 scores. This unobtrusive wearable seizure detection device was well received but had side effects. The current workflow and low performance limit its implementation in clinical practice. We suggest different steps to improve these performance metrics and patient experience.
No takes yet. Share an insight, caveat, or question.
Macea et al. (2023) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: