Answers are grounded in this paper and cite their sources.
Introduction: Lung stereotactic body radiation therapy (SBRT) often utilizes four-dimensional CT to quantify tumour motion. Respiratory gating delivers radiation only during a specific portion of the breathing cycle, potentially sparing healthy tissue. This study compares internal target volume/planning target volume (ITV/PTV) volumes and dosimetric outcomes between non-gated and gated (30–70% phase window) lung SBRT. Materials and Methods: Twenty-five stage-1 NSCLC cases were analysed. Non-gated plans used ITVs delineated on MIP images from all respiratory phases while Gated plans utilized ITVs from the 30–70% phase window. A 5 mm PTV margin was applied to both. Dosimetric parameters for PTV and organ at risks were compared based on RTOG 0915/0813 protocols. Results: Gated plans showed a significant reduction in mean ITV (22·02 Vs 11·83 cc; p < 0·001) and PTV (48·87 Vs 31·25 cc; p < 0·001) volumes. While PTV dose parameters and homogeneity indices of the plans were found to have no significant difference, gradient measure, gradient index and R50% showed a significant difference between the plans (p-value: < 0·001). The mean lung dose (Dmean) has been reduced by 0·75 Gy with significant reductions in V20Gy, V10Gy and V5Gy ( p < 0·001). Findings: Utilizing a 30–70% gating window significantly reduces target volumes and dose to the lung, heart, ribs and oesophagus. Gating is a highly effective motion management strategy for lung SBRT when balancing volumetric reduction against delivery efficiency.
No takes yet. Share an insight, caveat, or question.
Gopalakrishnan et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: