Why the study?
Do serial office self-recordings accurately estimate the 24-hour ambulatory mean blood pressure?
Do serial office self-recordings accurately estimate the 24-hour ambulatory mean blood pressure?
Serial self-measurements of blood pressure have high patient-specific variability and are too unreliable to accurately estimate true long-term 24-hour ambulatory blood pressure.
Answers are grounded in this paper and cite their sources.
High patient-specific variability supports caution with self BP for ambulatory estimation; leaves open prospective validation of repeatability.
The long-term true blood pressure, estimated in terms of the repeatable 24 h ambulatory mean (24 hAmb) pressure, is probably best related to progressive cardiovascular deterioration and is vital for clinical decision-making. Serial self-measurements (SELF) under quiet conditions may reflect this level, but with an annoying uncertainty in individual patients. This uncertainty is characterized by analyzing differences between the SELF readings of seated/supine patients on their own and the reference 24 hAmb values based on 72 recordings. From at-random replicated sessions of 59 subjects, the sources of uncertainty can be separated into three components: a systematic (non-random) variable difference in level from person to person, a mean systematic difference in level between methods, and random variability determining repeatability between sessions. An unstable alerting reaction distorts about six initial self-recordings and increases the random variability. The following 7-12 or 13-24 'steady-state' values show a comparable random variability but reflect the 24 hAmb level only when compared as the average of all patients. The standard deviation for repeatability is about 50-100% higher for SELF than for 24 hAmb. The patient-specific difference between methods contributes more than +/-10 mmHg to the uncertainty interval of the SELF results. These patient-specific differences recur at repeat sessions and thus cannot be reduced by averaging the results of sequential SELF sessions. In contrast, two 24 hAmb results provide a 95% uncertainty interval of +/-5 mm Hg. Thus, the averaged results of multiple SELF sessions can be used to detect major changes in blood pressure but are, as a result of patient-specific differences, too unreliable when the value to be estimated (the true value) is the expected long-term value of 24 hAmb results.
No takes yet. Share an insight, caveat, or question.
Pávek et al. (2002) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: