Why the study?
Does radiofrequency ablation on ECMO support provide a safe and effective treatment for infants with incessant tachyarrhythmias and haemodynamic collapse?
Does radiofrequency ablation on ECMO support provide a safe and effective treatment for infants with incessant tachyarrhythmias and haemodynamic collapse?
ECMO provides a haemodynamically stable platform for successful radiofrequency ablation in infants with incessant tachyarrhythmias, though technical modifications like low power delivery or irrigated tip catheters may be required.
May support RFA on ECMO as rescue in unstable infants; hypothesis-generating and needs prospective validation.
AIMS: To evaluate the use of extracorporeal membrane oxygenation (ECMO) in supporting infants who require radiofrequency ablation (RFA) for incessant tachyarrhythmias, with particular emphasis on modifications required to standard ablation techniques. METHODS AND RESULTS: Three cases of RFA carried out in infancy on ECMO support were reviewed retrospectively. Two infants with permanent junctional reciprocating tachycardia (PJRT) and one with ventricular tachycardia (VT) presented in a low cardiac output state, owing to cardiomyopathy caused by incessant tachycardia. In each case antiarrhythmic drug therapy caused haemodynamic collapse, requiring emergency ECMO support. Drug therapy on ECMO was not successful. In one patient, the tachycardia was controlled on ECMO with antiarrhythmic drugs, but recurred following ECMO decannulation. Each patient had a successful RFA on ECMO support. Power delivery was low during ablation lesions. In the PJRT cases power as low as 3-5 Watts was effective. In the VT ablation, an irrigated tip RFA catheter was required when cooling remained poor even after temporarily stopping ECMO flow. CONCLUSION: Extracorporeal membrane oxygenation provides a haemodynamically stable and safe platform for antiarrhythmic drug therapy and RFA in infants with incessant tachyarrhythmias. Once ECMO has been commenced, if the tachyarrhythmia remains difficult to control with antiarrhythmic drugs, RFA should be strongly considered, to avoid the risk of tachycardia recurrence following ECMO decannulation. Power delivery during ablation lesions may be low because of inadequate cooling of the catheter tip. Reducing or stopping flow in the ECMO circuit may not provide adequate cooling and an irrigated tip catheter may be required.
No takes yet. Share an insight, caveat, or question.
Shebani et al. (2015) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: