Provides normative data for 24-hour ambulatory blood pressure monitoring in normotensive subjects across different age groups to aid in the interpretation of hypertensive readings.
Supplies age-specific normative ambulatory BP values; extends reference data for ABPM interpretation but leaves open prospective outcome validation.
Ambulatory blood pressure monitoring has become increasingly popular for diagnosing and treating hypertension. However, data from normotensive subjects are needed for interpretation of hypertensive readings. Ambulatory blood pressure was monitored in 126 normotensive subjects (age range, 20 to 84 years). Mean systolic and diastolic blood pressures and blood pressure loads (percentage of systolic readings >140 mm Hg and diastolic readings >90 mm Hg) were obtained and interpreted. Mean awake systolic and diastolic pressures ranged from 125 ± 10 to 137 ± 17 mm Hg and 70 ± 8 to 71 ± 9 mm Hg, respectively. The systolic and diastolic trends of subjects' blood pressures taken during office visits and the 24-hour measurements were similar. Ranges for systolic and diastolic blood pressure loads from youngest to oldest ages were 9%± 14% to 25%±20% and 3%±7% to 4%±7%, respectively. A comparison of blood pressure means from our sample that were taken during office visits and blood pressure means from a 2122-patient community survey demonstrated that our sample was reflective of an unselected population. (JAMA. 1991;265:1414-1417)
No takes yet. Share an insight, caveat, or question.
P K Zachariah (1991) studied this question.