Answers are grounded in this paper and cite their sources.
In vitro study evaluates post-curing atmospheres' effects on hardness and conversion in 3D-printed occlusal splints, suggesting nitrogen-assisted methods enhance material properties.
Post-curing is a critical step in the fabrication of 3D-printed resin-based occlusal splints because it influences polymerization efficiency and final material properties. Atmospheric oxygen may inhibit free-radical polymerization at the resin surface, whereas nitrogen-assisted post-curing may reduce this effect. This in vitro study evaluated the effects of post-curing atmosphere and duration on the Vickers hardness and surface degree of conversion of a 3D-printed occlusal splint material. Sixty disc-shaped specimens (10 mm × 2 mm) were fabricated from a commercially available 3D-printable occlusal splint resin in six separate printing builds, with 10 specimens produced per build. The six builds were randomly assigned, one per condition, to nitrogen-assisted or ambient-air post-curing for 5, 10, or 20 min ( n = 10 per condition). Surface degree of conversion was determined using attenuated total reflectance Fourier transform infrared spectroscopy, and surface hardness was measured using a Vickers microhardness tester. Data were analyzed using two-way analysis of variance and Bonferroni-adjusted pairwise comparisons (α = 0.05). Post-curing atmosphere, duration, and their interaction significantly affected both surface degree of conversion and Vickers hardness ( p < 0.001). Post-curing duration showed the strongest effect on both outcomes. The highest surface degree of conversion was observed in the 20-min nitrogen-assisted group (89.97 ± 2.38%), followed by the 20-min ambient-air group (84.44 ± 2.38%). Similarly, the highest Vickers hardness was recorded in the 20-min nitrogen-assisted group (20.97 ± 0.95), followed by the 20-min ambient-air group (18.42 ± 0.50). Nitrogen-assisted post-curing produced significantly higher surface DC values than ambient-air post-curing at all durations, whereas a significant atmosphere-related difference in VHN was observed only at 20 min. Post-curing duration was the strongest factor affecting both outcomes. Nitrogen-assisted post-curing increased surface DC at all tested durations but produced a significantly higher VHN than ambient-air post-curing only after 20 min.
No takes yet. Share an insight, caveat, or question.
ABDULAI et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: