Evaluates DeepGuard-X for deepfake triage, suggesting improved accuracy and reliability.
Manipulated media evidence is now a routine feature of cybercrime casework, yet existing detection systems typically examine a single modality, return uncalibrated verdicts, and offer no mechanism for signaling their own uncertainty — a serious deficiency for any tool whose output may shape an investigation or inform legal proceedings. This paper presents DeepGuard-X, an explainable, uncertainty-aware, multi-modal fusion architecture for deepfake and manipulated-media triage, developed and evaluated under a strict held-out protocol in which no component — classifier, fusion weight, or uncertainty model — is ever scored on a case it observed during fitting. Independently calibrated image, video, and audio classifiers are combined through reliability-weighted log-odds fusion; Monte Carlo Dropout quantifies epistemic and aleatoric uncertainty; and non-circular, validation-selected thresholds drive a three-tier triage decision, with every verdict additionally backed by SHAP-based explainability. The architecture is evaluated on a newly constructed, literature-calibrated synthetic benchmark, DG-X SMFD v1.0 (50,000 cases, released publicly on Zenodo), designed to support reproducible methodology research pending access to licensed real-world deepfake corpora. On a genuinely held-out test split, the fused verdict achieves AUC-ROC = 0.9899 (95% CI [0.9878, 0.9918]), stable at 0.9894 ± 0.0004 across five independent seeds and substantially exceeding any individual modality (image 0.968, video 0.975, audio 0.863). A correlated-artifact stress test, an honestly-reported fusion-rule ablation, a variance-preserving adversarial evasion test, and a direct empirical comparison of epistemic and aleatoric uncertainty are all presented with findings reported exactly as observed — including an inconclusive fusion-rule comparison and a highly correlated (r = 0.91) uncertainty decomposition — rather than adjusted to fit a cleaner narrative. At its selected operating point, the triage layer resolves 60.1% of held-out cases automatically at 0.40% error, against a 4.91% unconditional baseline on the same split. Every result in this paper is explicitly scoped to synthetic data, and every identified limitation — including the absence of real-world validation, demographic fairness modeling, and human forensic-examiner evaluation — is discussed without exception. DeepGuard-X and its accompanying dataset are intended as a rigorously validated, fully reproducible reference architecture for future work incorporating genuine forensic media.
No takes yet. Share an insight, caveat, or question.
Suhail Ahmed Chandio (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: