Answers are grounded in this paper and cite their sources.
Fibers were prepared for second-harmonic generation by injecting a frequency-doubled (seed) signal with the fundamental light from a Nd:YAG laser. The relative phase shift between the seed and the second-harmonic light generated by the fiber was measured to be close to 90 degrees ( approximately 99 +/- 9.2 degrees ). A water cell was used to sweep the relative phase of the waves with interferometric precision. Some physical consequences of a pi/2 phase shift are pointed out.
No takes yet. Share an insight, caveat, or question.
Margulis et al. (1989) studied this question.