Key result
COVID-19 lockdown linked to ~77% fewer cardiology contacts without worsening remotely monitored heart failure.
Why the study?
Multiparametric remote monitoring of patients with HF has the potential to mitigate the health risks of lockdowns for COVID-19.
How did the first French COVID-19 national lockdown affect healthcare utilization, physiological parameters, and heart failure decompensations in chronic heart failure patients managed with multiparametric remote monitoring?
Cohort (n=51)
No
How did the first French COVID-19 national lockdown affect healthcare utilization, physiological parameters, and heart failure decompensations in chronic heart failure patients managed with multiparametric remote monitoring?
Multiparametric remote monitoring preserved clinical stability and enabled home management of five out of six acute heart failure decompensations despite a 77% drop in cardiology medical contacts during the first COVID-19 lockdown.
Answers are grounded in this paper and cite their sources.
Supports remote monitoring to maintain HF stability with fewer contacts; leaves open need for randomized confirmation.
Aims Multiparametric remote monitoring of patients with heart failure (HF) has the potential to mitigate the health risks of lockdowns for COVID-19. We aimed to compare healthcare use, physiological variables, and HF decompensations during 1 month before and during the first month of the first French national lockdown for COVID-19 among patients undergoing remote monitoring. Methods and results Transmitted vital parameters and data from cardiac implantable electronic devices were analysed in 51 patients. Medical contact was defined as the sum of visits and days of hospitalization. The lockdown was associated with a marked decrease in cardiology medical contact (118 days before vs. 26 days during, −77%, P = 0.003) and overall medical contact (180 days before vs. 79 days during, −58%, P = 0.005). Patient adherence with remote monitoring was 84 ± 21% before and 87 ± 19% during lockdown. The lockdown was not associated with significant changes in various parameters, including physical activity (2 ± 1 to 2 ± 1 h/day), weight (83 ± 16 to 83 ± 16 kg), systolic blood pressure (121 ± 19 to 121 ± 18 mmHg), heart rate (68 ± 10 to 67 ± 10 b.p.m.), heart rate variability (89 ± 44 to 78 ± 46 ms, P = 0.05), atrial fibrillation burden (84 ± 146 vs. 86 ± 146 h/month), or thoracic impedance (66 ± 8 to 66 ± 9 Ω). Seven cases of HF decompensations were observed before lockdown, all but one of which required hospitalization, vs. six during lockdown, all but one of which were managed remotely. Conclusions The lockdown restrictions caused a marked decrease in healthcare use but no significant change in the clinical status of HF patients under multiparametric remote monitoring.
No takes yet. Share an insight, caveat, or question.
Ploux et al. (2021) conducted a cohort in Chronic symptomatic heart failure under multiparametric remote monitoring (n=51). First French COVID-19 national lockdown under multiparametric remote monitoring (CareLine Solutions home sensors and CIED remote interrogation) vs. Pre-lockdown period (1 month prior to lockdown) was evaluated on Cardiology medical contact index (sum of in-person visits and days of hospitalization) (Relative reduction -77%, p=0.003). The COVID-19 lockdown reduced cardiology medical contact by 77% without altering clinical status or decompensations in remotely monitored heart failure patients.