Key result
Synthesized 18-lead ECG diagnosed STEMI in 54.5% of patients, accurately identifying the infarction site in 94.4% of those cases, particularly for right ventricular or posterior wall infarcts.
Why the study?
Does synthesized 18-lead ECG improve the accuracy of infarction site diagnosis in patients presenting with STEMI?
Observational (n=33)
Does synthesized 18-lead ECG improve the accuracy of infarction site diagnosis in patients presenting with STEMI?
Synthesized 18-lead ECG improves the identification of the infarction site in STEMI patients, particularly for right ventricular and posterior wall infarctions that are often missed by standard 12-lead ECG.
Answers are grounded in this paper and cite their sources.
Should not yet alter STEMI diagnostic practice; leaves open value of synthesized 18-lead ECG pending prospective validation.
OBJECTIVE: This was a pilot retrospective case-series study performed to investigate whether synthesized 18-lead electrocardiogram (ECG) could improve the accuracy of infarction site diagnosis in patients presenting with ST-elevation myocardial infarction (STEMI). METHOD: Of 103 consecutive patients with acute coronary syndrome who underwent emergency coronary angiography between October 1, 2014 and December 10, 2015, 33 patients fulfilling the diagnostic criteria for STEMI were enrolled in this study. RESULTS: leads), in addition to ST elevation in the standard 12-lead ECG, was lower in patients in whom the left anterior descending coronary artery (LAD) was the infarct-related coronary artery LAD vs. right coronary artery (RCA) vs. left circumflex coronary artery (LCX): 3/11 [27.3%] vs. 4/6 [66.7%] vs. 11/16 [68.6%], p=0.007). The above data indicate that the synthesized 18-lead ECG was useful for diagnosing STEMI in 18 of the 33 patients (54.5%). Furthermore, in 17 of the 18 patients (94.4%), the area of myocardium supplied by the infarct-related coronary artery was consistent with the site of infarction estimated from the ST elevation profile in the 6 synthesized leads. CONCLUSION: The diagnosis of STEMI by synthesized 18-lead ECG is useful to identify the site of infarction in patients with infarction of the right ventricular wall (supplied by the RCA) or posterior wall of the left ventricle (supplied by the LCX), which often fail to be diagnosed by the standard 12-lead ECG.
No takes yet. Share an insight, caveat, or question.
Ashida et al. (2016) conducted an observational in ST-elevation myocardial infarction (STEMI) (n=33). Synthesized 18-lead electrocardiogram (ECG) vs. Standard 12-lead ECG was evaluated on ST elevation in synthesized leads by infarct-related artery (LAD vs RCA vs LCX) (p=0.007). Synthesized 18-lead ECG diagnosed STEMI in 54.5% of patients, accurately identifying the infarction site in 94.4% of those cases, particularly for right ventricular or posterior wall infarcts.
Synapse has enriched 10 related papers. Consider them for comparative context: