Key result
Presence of an advisory ICD lead was associated with significantly higher ICD concerns scores than nonadvisory leads, both with (27.7 vs 18.5) and without (18.5 vs 10.8) prior shock (P=0.0001).
Why the study?
Does having an ICD lead under advisory increase psychological distress in patients with implantable cardioverter-defibrillators?
Observational (n=413)
Does having an ICD lead under advisory increase psychological distress in patients with implantable cardioverter-defibrillators?
Patients with an ICD lead under advisory experience significantly higher psychological distress and device-related concerns compared to those with non-advisory leads, independent of shock history.
Advisory leads may warrant distress screening in ICD recipients; leaves open causal mechanisms and targeted interventions.
BACKGROUND: Automatic implantable cardioverter-defibrillators (ICDs) are standard therapy for patients at high risk of sudden cardiac death. Device implantation is a stressful event that has been associated with patient and anticipatory anxiety. While the psychological effects of normally functioning ICDs are known, only a dearth of literature evaluates how a warning about the potential for malfunction of an ICD lead, related to a device advisory, influences the degree of psychological distress. These effects are evaluated in a patient population with the Medtronic Sprint Fidelis defibrillation lead 6949 (Medtronic, Minneapolis, MN, USA). METHODS: A sample of 413 patients were studied. Groups included 158 with an advisory Medtronic 6949 and 255 with an ICD that had no current advisories. Patients were administered a validated disease-specific metric assessing concerns over ICDs, as well as a demographics questionnaire. The primary outcome was the total score on the ICD concerns (ICDC). Analysis was with one-way Analysis of Variance with preplanned orthogonal contrasts and multivariate regression. RESULTS: The advisory group tended to have higher numbers of high school and college graduates. The average length of device implant in the nonadvisory group was higher at 4.29 years versus 3.99 years in the advisory group (t = 0.901, P ≤ 0.5). A higher percentage of those with an advisory experienced more shocks (39% vs 32%; z =-1.51, P ≤ 0.5). Average ICDC scores in the advisory group with previous shock were significantly higher than in the nonadvisory group with prior shock ([27.7 standard deviation (SD) ± 14.5] vs [18.5 SD ± 12.5], P = 0.0001) . Average ICDC score in the advisory group without shock was also significantly elevated compared to the nonadvisory group (18.5 SD ± 14.5 vs 10.8, SD ± 12.5, P = 0.0001). There was a significant effect of having an advisory on total ICDC scores (F = 21.32, P ≤ 0.0001). History of shock also significantly increased total ICDC scores (F = 20.07, P ≤ 0.0001). In multivariate regression, presence of Fidelis lead and history of shock were predictors for increased ICDC scores (R(2) = 0.158, F = 38.88, P = 0.0001). When controlling for shock history, presence of Fidelis lead remained an independent predictor of elevated ICDC scores (R(2) = 0.125, F = 59.30, P ≤ 0.0001). CONCLUSIONS: Our study attempts to address some of the psychological differences between participants with advisory and nonadvisory leads. Higher scores on the ICDC were found in our advisory group. While statistically significant, it is entirely unclear if these scale elevations are clinically significant or if directed counseling at this stage may reduce these elevations. This raises the suspicion that directed counseling be undertaken for patients with future advisories.
No takes yet. Share an insight, caveat, or question.
Heatherly et al. (2011) conducted an observational in Implantable cardioverter-defibrillators (n=413). Advisory Medtronic Sprint Fidelis defibrillation lead 6949 vs. ICD with no current advisories was evaluated on Total score on the ICD concerns (ICDC) (p=≤0.0001). Presence of an advisory ICD lead was associated with significantly higher ICD concerns scores than nonadvisory leads, both with (27.7 vs 18.5) and without (18.5 vs 10.8) prior shock (P=0.0001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: