Key result
Machine learning cuts optical flow velocity estimation error from ~54% to ~3% vs CFD ground truth.
Why the study?
Computational fluid dynamics is widely used to predict arterial hemodynamics but is poorly suited for clinical applications due to the complexity of numerical simulations.
Do machine learning algorithms improve the accuracy of blood flow velocity estimation from 2D projective angiography-like images processed with the optical flow method?
Do machine learning algorithms improve the accuracy of blood flow velocity estimation from 2D projective angiography-like images processed with the optical flow method?
Combining machine learning with optical flow methods on 2D projection images drastically reduces flow velocity estimation error compared to optical flow alone, offering a computationally efficient potential alternative to full 3D CFD simulations for evaluating hemodynamics from angiography.
Answers are grounded in this paper and cite their sources.
May enable efficient flow estimation from angiography; leaves open human validation before clinical use.
Computational fluid dynamics (CFD) is widely employed to predict hemodynamic characteristics in arterial models, while not friendly to clinical applications due to the complexity of numerical simulations. Alternatively, this work proposed a framework to estimate hemodynamics in vessels based on angiography images using machine learning (ML) algorithms. First, the iodine contrast perfusion in blood was mimicked by a flow of dye diffusing into water in the experimentally validated CFD modeling. The generated projective images from simulations imitated the counterpart of light passing through the flow field as an analogy of X-ray imaging. Thus, the CFD simulation provides both the ground truth velocity field and projective images of dye flow patterns. The rough velocity field was estimated using the optical flow method (OFM) based on 53 projective images. ML training with least absolute shrinkage, selection operator and convolutional neural network was conducted with CFD velocity data as the ground truth and OFM velocity estimation as the input. The performance of each model was evaluated based on mean absolute error and mean squared error, where all models achieved or surpassed the criteria of 3 × 10−3 and 5 × 10−7 m/s, respectively, with a standard deviation less than 1 × 10−6 m/s. Finally, the interpretable regression and ML models were validated with over 613 image sets. The validation results showed that the employed ML model significantly reduced the error rate from 53.5% to 2.5% on average for the v-velocity estimation in comparison with CFD. The ML framework provided an alternative pathway to support clinical diagnosis by predicting hemodynamic information with high efficiency and accuracy.
No takes yet. Share an insight, caveat, or question.
Padhee et al. (2022) studied Cardiovascular disease / Hemodynamics estimation. Machine learning algorithms (LASSO, MLP, CNN, LSTM) applied to optical flow method (OFM) velocity estimates from projective angiography-like images vs. Standard Optical Flow Method (OFM) alone compared against Computational Fluid Dynamics (CFD) ground truth was evaluated on Average error rate in v-velocity estimation compared with CFD ground truth (p=<0.01). Machine learning correction of optical flow method estimates reduced the average v-velocity estimation error rate from 53.5% to 2.5% compared with computational fluid dynamics ground truth.
Synapse has enriched 10 related papers. Consider them for comparative context: