Key result
The AFP surveillance system in Yemen met most WHO performance targets from 2010 to 2015, but failed to reach targets for specimen transport in 2011 and laboratory processing times in 2015.
Why the study?
Acute flaccid paralysis surveillance is an essential strategy for poliovirus eradication, prompting an evaluation of system performance and indicators across Yemeni governorates from 2010 to 2015.
Observational (n=3,019)
Yes
The AFP surveillance system in Yemen met most WHO indicators between 2010 and 2015, though weaknesses in specimen transport and laboratory feedback were identified.
Highlights logistical shortfalls in Yemen's AFP system; leaves open effects on polio detection.
BACKGROUND Acute flaccid paralysis (AFP) surveillance is an essential strategy for poliovirus eradication. OBJECTIVE This study aimed to evaluate the performance of the AFP surveillance system in Yemen from 2010 to 2015, identify components that require strengthening, and compare the indicators by year and governorates. METHODS This descriptive study was based on secondary analysis of AFP surveillance data reported during 2010-2015 from all Yemeni governorates. The World Health Organization (WHO) minimum performance standards were used to evaluate the performance of the AFP surveillance system. RESULTS A total of 3019 AFP cases were reported between January 2010 and December 2015. At the national level, AFP surveillance achieved WHO targets throughout the evaluating period for the nonpolio AFP rate of cases per 100,000 members of the population younger than 15 years of age, proportion of AFP cases reported within 7 days, proportion of AFP cases investigated within 48 hours of notification, proportion of AFP cases with two adequate stool specimens, and proportion of stool specimens from which nonpolio enterovirus was isolated. However, the proportion of specimens that arrived at the central level within 3 days of the first sample collection and the proportion of stool specimens with results sent from the reference laboratory within 28 days of receipt did not reach targets in 2011 and 2015, respectively. CONCLUSIONS The AFP surveillance system in Yemen has met most of the WHO indicator levels. Nevertheless, the evaluation showed areas of weakness regarding the arrival of specimens at the central level within 3 days of the first sample collection and delays in processing of the results and submitting feedback by the laboratory. Therefore, there is a need to strengthen the follow-up of specimens submitted to the laboratory.
No takes yet. Share an insight, caveat, or question.
Almoayed et al. (2019) conducted an observational in Acute flaccid paralysis (n=3,019). AFP surveillance system vs. WHO minimum performance standards was evaluated on WHO minimum performance standards for AFP surveillance. The AFP surveillance system in Yemen met most WHO performance targets from 2010 to 2015, but failed to reach targets for specimen transport in 2011 and laboratory processing times in 2015.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: