Key result
4D Flow CMR thresholds of 20 and 40 ml for regurgitant volume achieved the best agreement with TTE for grading mitral regurgitation (κ=0.93; 95% CI 0.8-1).
Why the study?
The optimal 4D Flow CMR thresholds that achieve the best agreement with TTE for grading mitral regurgitation were undetermined.
Do specific 4D Flow CMR thresholds improve agreement with transthoracic echocardiography for grading chronic primary mitral regurgitation?
Cohort (n=66)
Blinded
No
Do specific 4D Flow CMR thresholds improve agreement with transthoracic echocardiography for grading chronic primary mitral regurgitation?
Optimized 4D Flow CMR thresholds (20/40 ml for regurgitant volume and 20/37% for regurgitant fraction) provide excellent agreement with transthoracic echocardiography for grading primary mitral regurgitation.
Answers are grounded in this paper and cite their sources.
4D Flow CMR thresholds for MR grading need prospective validation; leaves open whether they improve decisions over TTE.
OBJECTIVES: To determine the 4D Flow Cardiac Magnetic Resonance (CMR) thresholds that achieve the best agreement with transthoracic echocardiography (TTE) for grading mitral regurgitation (MR). METHODS: We conducted a single-center prospective study of patients evaluated for chronic primary MR in 2016-2020. MR was evaluated blindly by TTE and 4D Flow CMR, respectively by two cardiologists and two radiologists with decades of experience. MR was graded with both methods as mild, moderate, or severe. 4D Flow CMR measurements included MR regurgitant volume per beat (RV) and mitral anterograde flow per beat (MF). RF was obtained as the ratio RV/MF. Additionally, MF was compared to left ventricular stroke volume (LVSV) by cine-CMR. RESULTS: We included 33 patients in the initial cohort and 33 in the validation cohort. Inter-observer agreement was excellent for 4D Flow CMR ICC = .94 (95% CI, .86-.97, p < 0.0001). Using recommended TTE thresholds (30 ml, 60 ml, 30%, 50%), agreement was moderate for RV and RF. The best agreement between 4D Flow CMR and TTE was obtained with CMR thresholds of 20 and 40 ml for RV (κ = .93; 95% CI, .8-1) and 20% and 37% for RF (κ = .90; 95% CI, .7-.9). In the validation cohort, agreement between TTE and 4D Flow CMR was good with the optimal thresholds (κ = .78; 95% CI, .61-.94). CONCLUSION: We propose CMR thresholds that provide a good agreement between TTE and CMR for grading MR. Further studies are needed to fully validate 4D-Flow CMR accuracy for primary MR quantification.
No takes yet. Share an insight, caveat, or question.
Ribeyrolles et al. (2022) conducted a cohort in Chronic primary mitral regurgitation (n=66). 4D Flow Cardiac Magnetic Resonance (CMR) vs. Transthoracic echocardiography (TTE) was evaluated on Agreement between 4D Flow CMR and TTE for grading mitral regurgitation (κ = 0.93, 95% CI 0.8-1). 4D Flow CMR thresholds of 20 and 40 ml for regurgitant volume achieved the best agreement with TTE for grading mitral regurgitation (κ=0.93; 95% CI 0.8-1).