Key result
Atrial arrhythmia recurrences following cryoballoon pulmonary vein isolation were associated with focal pulmonary vein reconnections in 64% of initially isolated veins, which were readily ablated with focal radiofrequency delivery.
Population
44 patients who underwent a second ablation procedure using radiofrequency catheter for recurrent atrial…
Design
Cohort
Follow-up
7.7 ± 9 months (time to redo procedure)
Authors
Loading...
Focal reconnections may guide redo ablation after cryoballoon PVI; hypothesis-generating for recurrence mechanisms and requires prospective validation.
Observational (n=44)
No
Atrial arrhythmia recurrences after cryoballoon pulmonary vein isolation are associated with focal reconnections at preferential anatomical sites, which can be effectively treated with focal radiofrequency ablation.
Godin et al. (2013) conducted an observational in Paroxysmal Atrial Fibrillation (n=44). Radiofrequency redo ablation was evaluated on Pulmonary vein reconduction. Atrial arrhythmia recurrences following cryoballoon pulmonary vein isolation were associated with focal pulmonary vein reconnections in 64% of initially isolated veins, which were readily ablated with focal radiofrequency delivery.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: