Key result
A larger box lesion surface area as a ratio of total left atrial surface area protected against atrial fibrillation or atrial tachycardia recurrence after ablation.
Why the study?
Box lesion surface area size varies by individual anatomy, and its impact as a ratio of total LA surface area on arrhythmia recurrence had not been evaluated.
Does a larger left atrial box surface ratio prevent arrhythmia recurrence in patients with persistent atrial fibrillation undergoing ablation?
Cohort (n=70)
No
Does a larger left atrial box surface ratio prevent arrhythmia recurrence in patients with persistent atrial fibrillation undergoing ablation?
Answers are grounded in this paper and cite their sources.
A larger box lesion surface area relative to total left atrial surface area is independently associated with a lower risk of atrial fibrillation or atrial tachycardia recurrence after ablation for persistent AF.
BACKGROUND: The posterior wall of the left atrium (LA) is a well-known substrate for atrial fibrillation (AF) maintenance. Isolation of the posterior wall between the pulmonary veins (box lesion) may improve ablation success. Box lesion surface area size varies depending on the individual anatomy. This retrospective study evaluates the influence of box lesion surface area as a ratio of total LA surface area (box surface ratio) on arrhythmia recurrence. METHODS: Seventy consecutive patients with persistent AF (63 ± 11 years, 53 men) undergoing computed tomography (CT) imaging and ablation procedure consisting of a first box lesion were included in this study. Box lesion surface area was measured on electroanatomical maps and total LA surface area was derived from CT. Patients were followed with 24-h electrocardiography and exercise tests at 3, 6, and 12 months after AF ablation. Arrhythmia recurrence was defined as any AF/atrial tachycardia (AT) beyond 3 months without antiarrhythmic drugs. RESULTS: During a median follow-up of 13 (interquartile range = 10-17) months, 42 (60%) patients had AF/AT recurrence. Multivariate Cox proportional regression analysis showed that a larger box surface ratio protected against recurrence (hazard ratio [HR] = 0.81; 95% confidence interval [CI] = 0.690-0.955; P = 0.012). Left atrial volume index (HR = 1.01 [0.990-1.024, P = 0.427] and a history of mitral valve surgery (HR = 2.90; 95% CI = 0.970-8.693; P = 0.057) were not associated with AF recurrence in multivariate analysis. CONCLUSION: A larger box lesion surface area as a ratio of total LA surface area is protective for AF/AT recurrence after ablation for persistent AF.
No takes yet. Share an insight, caveat, or question.
Keçe et al. (2018) conducted a cohort in Persistent atrial fibrillation (n=70). Larger box surface ratio vs. Smaller box surface ratio was evaluated on Arrhythmia recurrence (any AF/AT beyond 3 months without antiarrhythmic drugs) (HR 0.81, 95% CI 0.690-0.955, p=0.012). A larger box lesion surface area as a ratio of total left atrial surface area protected against atrial fibrillation or atrial tachycardia recurrence after ablation.