Answers are grounded in this paper and cite their sources.
The subjective Chinese (Mandarin) articulation scores of a total of 50 sound conditions, namely at 12 receiver positions in four rooms, were obtained by expert listeners based on in-situ measured binaural room impulse responses (BRIRs) and binaural technology for headphone reproduction from a phonetically balanced test. The relationship between Chinese speech articulation scores and the speech transmission index (STI) according to IEC 60268-16 was established. The spectrum difference between the average spectrum of Chinese and that recommended by IEC may noticeably influence the measurement results with a STI difference of up to 0.054. However, the STI method can evaluate Chinese intelligibility without modulating the correction factor values recommended by IEC; the standard deviation between the articulation scores and the curve was 5.70%, which is relatively small.
No takes yet. Share an insight, caveat, or question.
Zhu et al. (2014) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: