Key result
In a porcine model, NIR-I fluorophores evaluated in the NIR-II window showed a mean fluorescence intensity of 0.4 ± 0.106 a.u. in small bowel catheters and 0.09 ± 0.039 a.u. in gastric catheters.
Why the study?
Fluorescence-guided surgery in the NIR-I window has constraints including limited penetration and scattering, making the exploration of NIR-I dye performance in the NIR-II window crucial.
In vivo evaluation confirms that NIR-I dyes can be successfully applied in the NIR-II domain for fluorescence-guided surgery.
Animal data support NIR-II feasibility for NIR-I dyes in GI models; leaves open human translation in fluorescence-guided surgery.
Over the last decade fluorescence-guided surgery has been primarily focused on the NIR-I window. However, the NIR-I window has constraints, such as limited penetration and scattering. Consequently, exploring the performance of NIR-I dyes at longer wavelengths (i.e., the NIR-II window) is crucial to expanding its application. Two fluorophores were used in three pigs to identify the mean fluorescence intensity (MFI) using two commercially available NIR-I and NIR-II cameras. The near-infrared coating of equipment (NICE) was used to identify endoluminal surgical catheters and indocyanine green (ICG) for common bile duct (CBD) characterization. The NIR-II window evaluation showed an MFI of 0.4 arbitrary units (a.u.) ± 0.106 a.u. in small bowel NICE-coated catheters and an MFI of 0.09 a.u. ± 0.039 a.u. in gastric ones. In CBD characterization, the ICG MFI was 0.12 a.u. ± 0.027 a.u., 0.18 a.u. ± 0.100 a.u., and 0.22 a.u. ± 0.041 a.u. at 5, 35, and 65 min, respectively. This in vivo imaging evaluation of NIR-I dyes confirms its application in the NIR-II domain. To the best of our knowledge, this is the first study assessing the MIF of NICE in the NIR-II window using a commercially available system. Further comparative trials are necessary to determine the superiority of NIR-II imaging systems.
No takes yet. Share an insight, caveat, or question.
Rodríguez‐Luna et al. (2022) studied this question. NIR-I fluorophores (NICE and ICG) was evaluated on Mean fluorescence intensity (MFI). In a porcine model, NIR-I fluorophores evaluated in the NIR-II window showed a mean fluorescence intensity of 0.4 ± 0.106 a.u. in small bowel catheters and 0.09 ± 0.039 a.u. in gastric catheters.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: