Transient electric birefringence experiments have been performed on well‐characterized highly monodisperse samples of tobacco mosaic virus (TMV). Experiments and calculations are presented that show that the sensitivity and accuracy of the traditional transient electric birefringence technique can be enhanced by several orders of magnitude through the use of a low‐powered laser and crystal polarizing optics, signal averaging, and digital data processing. Measurements of the field‐free decay of the birefringence yield for the rotational diffusion coefficient, D R = 318 ± 3 sec −1 . The length of the rodlike virion, calculated from the Broersma equation with this value of D R and a rod diameter of 15 nm, is 292.5 ± 1.0 nm. Measurements of the growth of the birefringence when an electric field is applied across the sample yield μ 2 / k T (α ∥ − α ⊥ ) = 0.47 ± 0.07, where μ is the permanent dipole moment (assumed parallel to the symmetry axis of the virus) and α ∥ − α ⊥ is the electrical polarizability anistropy of the virus. Using the value of α ∥ − α ⊥ measured by O'Konski et al., we then obtain μ = 2.5 × 10 −14 esu cm.