This is the authors' abstract. We don't add key points for this paper.
The single-phase-to-ground (SPG) fault at the valve side of the converter transformer is one of the key challenges for modular multilevel converter (MMC)-based bipolar multi-terminal direct current (MTDC) systems. This fault may cause severe submodule (SM) capacitor overvoltage, prevent the operation of AC circuit breaker from quickly isolating the fault, and affect the normal operation of healthy MMCs. In this paper, an asymmetric crossing thyristor (ACT)-based MMC is proposed, which can handle the valve-side SPG faults in bipolar MTDC systems with the advantages of low SM capacitor overvoltage, low semiconductor cost, and no arm overcurrent. In addition, the proposed method has little impact on the healthy MMCs. Simulations using PSCAD and experimental studies with a down-scale prototype are conducted to verify the effectiveness of the proposed ACT-MMC and its protection operation.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Li et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: